FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

1208768006: Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta (disorder)


Status: current, Primitive. Date: 31-Mar 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4970892017 Aortic endoleak en Synonym Active Case insensitive SNOMED CT core
4970893010 Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta en Synonym Active Case insensitive SNOMED CT core
4970894016 Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta (disorder) en Fully specified name Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta Is a Disorder following clinical procedure false Inferred relationship Some
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta Is a Arterial complication of procedure true Inferred relationship Some
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta Following Endovascular insertion of stent graft true Inferred relationship Some 2
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta Finding site Aortic structure true Inferred relationship Some 1
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta Is a Complication associated with device false Inferred relationship Some
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta Is a Disorder of aorta true Inferred relationship Some
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta Associated with Aortic endovascular stent graft true Inferred relationship Some 3
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta Is a Complication of implant true Inferred relationship Some
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft into aorta Is a Postoperative complication true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Clinical finding foundation reference set

Cardiovascular finding reference set

Problem/Diagnosis reference set

Back to Start