Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
15954012 | Check artificial pacemaker | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
3390560018 | vérification du stimulateur cardiaque | fr | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Common French translation module (core metadata concept) |
391661000241116 | vérification du stimulateur cardiaque (intervention) | fr | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Common French translation module (core metadata concept) |
833752016 | Check artificial pacemaker (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Check artificial pacemaker | méthode (attribut) | Management - action | false | Inferred relationship | Some | ||
Check artificial pacemaker | est un(e) (attribut) | Analysis of electronic device used in cardiovascular system | false | Inferred relationship | Some | ||
Check artificial pacemaker | dispositif servant à une intervention (attribut) | Device(s) | false | Inferred relationship | Some | ||
Check artificial pacemaker | est un(e) (attribut) | Interrogation of cardiac pacemaker (procedure) | true | Inferred relationship | Some | ||
Check artificial pacemaker | dispositif servant à une intervention (attribut) | stimulateur cardiaque | true | Inferred relationship | Some | 1 | |
Check artificial pacemaker | localisation de l'intervention (attribut) | Structure of cardiovascular system (body structure) | false | Inferred relationship | Some | ||
Check artificial pacemaker | Direct device | dispositif biomédical | false | Inferred relationship | Some |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
vérification d'un stimulateur cardiaque pour l'impédance d'électrode | est un(e) (attribut) | True | Check artificial pacemaker | Inferred relationship | Some | |
vérification d'un stimulateur cardiaque pour artéfact en forme d'onde | est un(e) (attribut) | True | Check artificial pacemaker | Inferred relationship | Some | |
vérification d'un stimulateur cardiaque pour seuil d'intensité de courant | est un(e) (attribut) | True | Check artificial pacemaker | Inferred relationship | Some | |
Artificial pacemaker rate check | est un(e) (attribut) | True | Check artificial pacemaker | Inferred relationship | Some | |
Check artificial pacemaker for voltage threshold | est un(e) (attribut) | True | Check artificial pacemaker | Inferred relationship | Some |
Reference Sets