FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

89511008: Check artificial pacemaker for voltage threshold (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
148407013 Check artificial pacemaker for voltage threshold en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
212301000077110 vérification du seuil de tension d'un stimulateur cardiaque fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Common French translation module (core metadata concept)
489381000077111 vérification du seuil de tension d'un stimulateur cardiaque (intervention) fr Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Common French translation module (core metadata concept)
832421012 Check artificial pacemaker for voltage threshold (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Check artificial pacemaker for voltage threshold méthode (attribut) Management - action false Inferred relationship Some
Check artificial pacemaker for voltage threshold méthode (attribut) Maintenance - action (qualifier value) false Inferred relationship Some 1
Check artificial pacemaker for voltage threshold dispositif servant à une intervention (attribut) Device(s) false Inferred relationship Some 1
Check artificial pacemaker for voltage threshold dispositif servant à une intervention (attribut) stimulateur cardiaque false Inferred relationship Some 1
Check artificial pacemaker for voltage threshold est un(e) (attribut) Maintenance procedure for cardiac pacemaker system true Inferred relationship Some
Check artificial pacemaker for voltage threshold est un(e) (attribut) Check artificial pacemaker true Inferred relationship Some
Check artificial pacemaker for voltage threshold est un(e) (attribut) Maintenance of device false Inferred relationship Some
Check artificial pacemaker for voltage threshold Direct device stimulateur cardiaque false Inferred relationship Some 1
Check artificial pacemaker for voltage threshold Procedure site - Indirect (attribute) cœur false Inferred relationship Some 1
Check artificial pacemaker for voltage threshold Direct device implant cardiaque false Inferred relationship Some 1
Check artificial pacemaker for voltage threshold Direct device stimulateur cardiaque false Inferred relationship Some 1
Check artificial pacemaker for voltage threshold méthode (attribut) Maintenance - action (qualifier value) false Inferred relationship Some 1
Check artificial pacemaker for voltage threshold dispositif servant à une intervention (attribut) stimulateur cardiaque true Inferred relationship Some 1
Check artificial pacemaker for voltage threshold méthode (attribut) Maintenance - action false Inferred relationship Some 1
Check artificial pacemaker for voltage threshold localisation de l'intervention (attribut) Cardiac structure false Inferred relationship Some
Check artificial pacemaker for voltage threshold Direct device stimulateur cardiaque false Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Service and/or activities performed or intended to be performed for the client reference set (foundation metadata concept)

Back to Start