Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2015. Module: SNOMED CT core
Descriptions:
| Id | Description | Lang | Type | Status | Case? | Module |
| 3011896011 | Fluoroscopy guided revision of cardiac pacemaker electrode | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
| 3012160013 | Revision of cardiac pacemaker electrode using fluoroscopic guidance | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
| 3012478012 | Revision of cardiac pacemaker electrode using fluoroscopic guidance (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
| Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | est un(e) (attribut) | Fluoroscopy guided cardiac pacemaker procedure | true | Inferred relationship | Some | ||
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | est un(e) (attribut) | Operation on heart | true | Inferred relationship | Some | ||
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | est un(e) (attribut) | Cardiac fluoroscopy | true | Inferred relationship | Some | ||
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | est un(e) (attribut) | Revision | true | Inferred relationship | Some | ||
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | est un(e) (attribut) | intervention sur un stimulateur cardiaque | false | Inferred relationship | Some | ||
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | est un(e) (attribut) | guidage fluoroscopique | false | Inferred relationship | Some | ||
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | indication de reprise (attribut) | valeur numérique de la révision | true | Inferred relationship | Some | 2 | |
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | méthode (attribut) | Surgical action | true | Inferred relationship | Some | 2 | |
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | Direct device | Cardiac pacemaker electrode | true | Inferred relationship | Some | 2 | |
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | Procedure site - Indirect (attribute) | cœur | true | Inferred relationship | Some | 2 | |
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | méthode (attribut) | Fluoroscopic imaging - action | true | Inferred relationship | Some | 3 | |
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | a pour but (attribut) | Guidance intent (qualifier value) | true | Inferred relationship | Some | 3 | |
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | Procedure site - Direct (attribute) | cœur | true | Inferred relationship | Some | 3 | |
| Revision of cardiac pacemaker electrode using fluoroscopic guidance | est un(e) (attribut) | Biomedical equipment procedure (procedure) | true | Inferred relationship | Some |
| Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets