FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

68280004: Replacement of percutaneous drainage catheter with contrast monitoring (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
113413014 Replacement of percutaneous drainage catheter with contrast monitoring en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
808097016 Replacement of percutaneous drainage catheter with contrast monitoring (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of percutaneous drainage catheter with contrast monitoring substance utilisée (attribut) Radiographic contrast media (product) false Inferred relationship Some
Replacement of percutaneous drainage catheter with contrast monitoring méthode (attribut) Reimplantation - action false Inferred relationship Some
Replacement of percutaneous drainage catheter with contrast monitoring Using cathéter (objet physique) false Inferred relationship Some
Replacement of percutaneous drainage catheter with contrast monitoring localisation de l'intervention (attribut) structure corporelle false Inferred relationship Some 2
Replacement of percutaneous drainage catheter with contrast monitoring localisation de l'intervention (attribut) structure corporelle false Inferred relationship Some 7
Replacement of percutaneous drainage catheter with contrast monitoring méthode (attribut) action : remplacement false Inferred relationship Some 2
Replacement of percutaneous drainage catheter with contrast monitoring substance utilisée (attribut) Contrast media (substance) false Inferred relationship Some
Replacement of percutaneous drainage catheter with contrast monitoring est un(e) (attribut) Replacement of catheter true Inferred relationship Some
Replacement of percutaneous drainage catheter with contrast monitoring est un(e) (attribut) Diagnostic radiography with contrast media true Inferred relationship Some
Replacement of percutaneous drainage catheter with contrast monitoring utilisant une substance Contrast media (substance) false Inferred relationship Some 1
Replacement of percutaneous drainage catheter with contrast monitoring utilisant une substance Contrast media (substance) true Inferred relationship Some 1
Replacement of percutaneous drainage catheter with contrast monitoring méthode (attribut) action : imagerie radiographique true Inferred relationship Some 1
Replacement of percutaneous drainage catheter with contrast monitoring méthode (attribut) action : remplacement true Inferred relationship Some 2
Replacement of percutaneous drainage catheter with contrast monitoring Direct device cathéter (objet physique) true Inferred relationship Some 2
Replacement of percutaneous drainage catheter with contrast monitoring méthode (attribut) action : imagerie radiographique false Inferred relationship Some 1
Replacement of percutaneous drainage catheter with contrast monitoring Direct device cathéter (objet physique) false Inferred relationship Some 2
Replacement of percutaneous drainage catheter with contrast monitoring Direct device appareil false Inferred relationship Some
Replacement of percutaneous drainage catheter with contrast monitoring a pour but (attribut) à visée diagnostique false Inferred relationship Some
Replacement of percutaneous drainage catheter with contrast monitoring méthode (attribut) Investigation - action false Inferred relationship Some
Replacement of percutaneous drainage catheter with contrast monitoring méthode (attribut) Implantation - action false Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start