FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

66718009: Check artificial pacemaker by slew rate check (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
110835010 Check artificial pacemaker by slew rate check en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
197801000077115 vérification de la variation d'amplitude du signal d'un stimulateur fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Common French translation module (core metadata concept)
474021000077118 vérification de la variation d'amplitude du signal d'un stimulateur (intervention) fr Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Common French translation module (core metadata concept)
806362018 Check artificial pacemaker by slew rate check (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Check artificial pacemaker by slew rate check méthode (attribut) Management - action false Inferred relationship Some
Check artificial pacemaker by slew rate check méthode (attribut) Maintenance - action (qualifier value) false Inferred relationship Some 1
Check artificial pacemaker by slew rate check est un(e) (attribut) Maintenance procedure for cardiac pacemaker system true Inferred relationship Some
Check artificial pacemaker by slew rate check est un(e) (attribut) Artificial pacemaker rate check true Inferred relationship Some
Check artificial pacemaker by slew rate check dispositif servant à une intervention (attribut) Device(s) false Inferred relationship Some 1
Check artificial pacemaker by slew rate check dispositif servant à une intervention (attribut) stimulateur cardiaque false Inferred relationship Some 2
Check artificial pacemaker by slew rate check est un(e) (attribut) Maintenance of device false Inferred relationship Some
Check artificial pacemaker by slew rate check Direct device stimulateur cardiaque false Inferred relationship Some 1
Check artificial pacemaker by slew rate check Procedure site - Indirect (attribute) cœur false Inferred relationship Some 1
Check artificial pacemaker by slew rate check Direct device implant cardiaque false Inferred relationship Some 1
Check artificial pacemaker by slew rate check Direct device stimulateur cardiaque false Inferred relationship Some 1
Check artificial pacemaker by slew rate check méthode (attribut) Maintenance - action (qualifier value) false Inferred relationship Some 1
Check artificial pacemaker by slew rate check dispositif servant à une intervention (attribut) stimulateur cardiaque true Inferred relationship Some 1
Check artificial pacemaker by slew rate check Direct device stimulateur cardiaque false Inferred relationship Some 1
Check artificial pacemaker by slew rate check localisation de l'intervention (attribut) Cardiac structure false Inferred relationship Some
Check artificial pacemaker by slew rate check méthode (attribut) Maintenance - action false Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Service and/or activities performed or intended to be performed for the client reference set (foundation metadata concept)

Back to Start