FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

450820006: Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2012. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2917037017 Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2917043015 Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance est un(e) (attribut) guidage fluoroscopique true Inferred relationship Some
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance méthode (attribut) Fluoroscopic imaging - action false Inferred relationship Some 3
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance a pour but (attribut) Guidance intent (qualifier value) false Inferred relationship Some 3
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance est un(e) (attribut) Replacement of device (procedure) true Inferred relationship Some
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance est un(e) (attribut) Removal of cardiac pacemaker true Inferred relationship Some
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance méthode (attribut) action : remplacement true Inferred relationship Some 3
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Direct device Pacemaker pulse generator true Inferred relationship Some 3
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Indirect device Permanent cardiac pacemaker, device (physical object) true Inferred relationship Some 3
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance méthode (attribut) Fluoroscopic imaging - action true Inferred relationship Some 2
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance a pour but (attribut) Guidance intent (qualifier value) true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets