FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

395721008: Removal of electronic stimulator of brain with synchronous replacement (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2003. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
1469661011 Removal of electronic stimulator of brain with synchronous replacement (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
1489364019 Removal of electronic stimulator of brain with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1494701010 Removal of neurostimulator of brain with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1494702015 Removal of intracranial neuropacemaker with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1494703013 Removal of intracranial neurostimulator with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1494704019 Removal of intracranial pacemaker with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1494705018 Removal of intracranial electronic stimulator with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Removal of electronic stimulator of brain with synchronous replacement (procedure) Direct device Neurostimulator true Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) est un(e) (attribut) Removal of device from central nervous system true Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) est un(e) (attribut) intervention sur un stimulateur cardiaque false Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) est un(e) (attribut) retrait d'un dispositif thérapeutique false Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) est un(e) (attribut) Operation on brain false Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) méthode (attribut) Surgical action false Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) méthode (attribut) Removal - action false Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) Direct device Neuropacemaker device false Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) localisation de l'intervention (attribut) structure de l'encéphale false Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) localisation de l'intervention (attribut) structure de l'encéphale false Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) localisation de l'intervention (attribut) structure de l'encéphale false Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) localisation de l'intervention (attribut) structure de l'encéphale false Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) est un(e) (attribut) Replacement of device (procedure) true Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) méthode (attribut) action : remplacement false Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) Procedure site - Indirect (attribute) structure de l'encéphale false Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) est un(e) (attribut) Removal of object from brain tissue false Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) est un(e) (attribut) Operation on brain true Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) méthode (attribut) Surgical action true Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) Direct device Neuropacemaker device false Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) méthode (attribut) action : remplacement true Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) Procedure site - Indirect (attribute) structure de l'encéphale true Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) localisation de l'intervention (attribut) structure de l'encéphale true Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) est un(e) (attribut) Removal of device from head true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Service and/or activities performed or intended to be performed for the client reference set (foundation metadata concept)

Operating room procedures performed reference set (foundation metadata concept)

Back to Start