FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

303900001: Radionuclide water and electrolyte study (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
446129010 Radionuclide water and electrolyte study en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
700137018 Radionuclide water and electrolyte study (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


6 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Radionuclide water and electrolyte study est un(e) (attribut) examens radio-isotopiques du métabolisme true Inferred relationship Some
Radionuclide water and electrolyte study substance utilisée (attribut) Radioactive isotope false Inferred relationship Some 1
Radionuclide water and electrolyte study méthode (attribut) Introduction - action false Inferred relationship Some 1
Radionuclide water and electrolyte study utilisant une substance Radioactive isotope true Inferred relationship Some 2
Radionuclide water and electrolyte study est un(e) (attribut) imagerie true Inferred relationship Some
Radionuclide water and electrolyte study méthode (attribut) Investigation - action false Inferred relationship Some
Radionuclide water and electrolyte study méthode (attribut) action : imagerie isotopique true Inferred relationship Some 1
Radionuclide water and electrolyte study a pour but (attribut) à visée diagnostique false Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Radiocalcium absorption study est un(e) (attribut) True Radionuclide water and electrolyte study Inferred relationship Some
Potassium 40 whole body count est un(e) (attribut) True Radionuclide water and electrolyte study Inferred relationship Some
Total exchangeable sodium measurement est un(e) (attribut) True Radionuclide water and electrolyte study Inferred relationship Some
Total exchangeable potassium measurement est un(e) (attribut) True Radionuclide water and electrolyte study Inferred relationship Some
Total body water measurement est un(e) (attribut) False Radionuclide water and electrolyte study Inferred relationship Some
Extracellular fluid volume measurement est un(e) (attribut) True Radionuclide water and electrolyte study Inferred relationship Some
24 hour diphosphonate retention study est un(e) (attribut) True Radionuclide water and electrolyte study Inferred relationship Some

This concept is not in any reference sets

Back to Start