719604002: Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2017. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4008945017 Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4008946016 Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
4008947013 Fluoroscopy guided insertion of bioabsorbable arterial stent with contrast en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4008948015 Fluoroscopy guided insertion of bioabsorbable stent into artery with contrast en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Is a Insertion of arterial stent true Inferred relationship Some
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Is a Fluoroscopic angiography with contrast (procedure) true Inferred relationship Some
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Is a Insertion of stent using fluoroscopic guidance (procedure) true Inferred relationship Some
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Is a Procedure on artery using imaging guidance (procedure) true Inferred relationship Some
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Is a Biomedical equipment procedure (procedure) false Inferred relationship Some
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Method Insertion - action (qualifier value) false Inferred relationship Some 2
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Direct device Bioabsorbable vascular stent false Inferred relationship Some 2
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Procedure site - Indirect (attribute) Arterial structure true Inferred relationship Some 2
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 3
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Has intent Guidance intent (qualifier value) false Inferred relationship Some 3
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Arterial structure false Inferred relationship Some 3
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Is a Angiography using contrast true Inferred relationship Some
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 1
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 1
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Arterial structure true Inferred relationship Some 1
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Using substance (attribute) Contrast media (substance) true Inferred relationship Some 1
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Is a Fluoroscopy guided vascular stent procedure true Inferred relationship Some
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Direct device Bioabsorbable arterial stent true Inferred relationship Some 2
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Is a Vascular surgery procedure false Inferred relationship Some
Insertion of bioabsorbable stent into artery using fluoroscopic guidance with contrast (procedure) Method Surgical insertion - action (qualifier value) true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start