FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

252447004: Pulsed wave ultrasonic Doppler (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
376014019 Pulsed wave ultrasonic Doppler en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
376015018 PW - Pulsed wave ultrasonic Doppler en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
643078015 Pulsed wave ultrasonic Doppler (procedure) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core


2 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Pulsed wave ultrasonic Doppler Is a diagnostic Doppler ultrasonography false Inferred relationship Some
Pulsed wave ultrasonic Doppler Procedure site Blood vessel structure (body structure) false Inferred relationship Some 2
Pulsed wave ultrasonic Doppler Method Investigation - action false Inferred relationship Some
Pulsed wave ultrasonic Doppler Method Ultrasound imaging - action (qualifier value) false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Method Measurement - action false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Has intent Diagnostic intent (qualifier value) false Inferred relationship Some 2
Pulsed wave ultrasonic Doppler Method Evaluation - action false Inferred relationship Some 2
Pulsed wave ultrasonic Doppler Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Procedure site - Direct (attribute) Blood vessel structure (body structure) false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Using device (attribute) Doppler device false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Procedure site - Direct (attribute) Blood vessel structure (body structure) false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Method Ultrasound imaging - action (qualifier value) false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Has intent Diagnostic intent (qualifier value) false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Method Ultrasound imaging - action (qualifier value) false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Using device (attribute) Doppler device false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Procedure site - Direct (attribute) Blood vessel structure (body structure) false Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Method Doppler pulsed - action (qualifier value) true Inferred relationship Some 1
Pulsed wave ultrasonic Doppler Is a Doppler ultrasonography true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Unidirectional pulsed wave ultrasonic Doppler Is a True Pulsed wave ultrasonic Doppler Inferred relationship Some
Bidirectional pulsed wave ultrasonic Doppler (procedure) Is a True Pulsed wave ultrasonic Doppler Inferred relationship Some

This concept is not in any reference sets

Back to Start