FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

163020007: On examination - blood pressure reading (finding)


    Status: retired, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2021. Module: SNOMED CT core

    Descriptions:

    Id Description Lang Type Status Case? Module
    254063019 O/E - blood pressure reading en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
    254064013 O/E - blood pressure en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
    254065014 O/E - BP reading en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
    2561363010 On examination - blood pressure reading (finding) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
    2667419011 On examination - blood pressure reading en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
    109881000077119 à l'examen : lecture de la pression sanguine fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module


    0 descendants.

    Expanded Value Set


    Outbound Relationships Type Target Active Characteristic Refinability Group Values
    à l'examen : lecture de la pression sanguine Is a à l'examen : système cardiovasculaire false Inferred relationship Some
    à l'examen : lecture de la pression sanguine Associated finding Finding of systemic arterial pressure false Inferred relationship Some
    à l'examen : lecture de la pression sanguine Is a à l'examen : constatations spécifiées false Inferred relationship Some
    à l'examen : lecture de la pression sanguine Is a Clinical finding present false Inferred relationship Some
    à l'examen : lecture de la pression sanguine Finding context (attribute) Known present (qualifier value) false Inferred relationship Some 1
    à l'examen : lecture de la pression sanguine Associated finding Blood pressure finding (finding) false Inferred relationship Some 1
    à l'examen : lecture de la pression sanguine Temporal context (attribute) Current false Inferred relationship Some 1
    à l'examen : lecture de la pression sanguine Subject relationship context (attribute) Subject of record (person) false Inferred relationship Some 1
    à l'examen : lecture de la pression sanguine Is a Blood pressure finding (finding) false Inferred relationship Some
    à l'examen : lecture de la pression sanguine Finding informer (attribute) Performer of method (person) false Inferred relationship Some 3
    à l'examen : lecture de la pression sanguine Interprets Blood pressure false Inferred relationship Some 2
    à l'examen : lecture de la pression sanguine Finding method (attribute) Physical examination false Inferred relationship Some 4
    à l'examen : lecture de la pression sanguine Finding site Structure of cardiovascular system (body structure) false Inferred relationship Some 1

    Inbound Relationships Type Active Source Characteristic Refinability Group
    On examination - blood pressure unrecordable Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    à l'examen : lecture basse de la pression sanguine Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - blood pressure reading normal Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - blood pressure reading raised Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - blood pressure reading: postural drop Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - Systolic blood pressure reading Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - Diastolic blood pressure reading Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - blood pressure stable Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - blood pressure decreased Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - blood pressure labile Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - initial high blood pressure Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - check high blood pressure Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - Arterial pressure index normal Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - Arterial pressure index abnormal Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    à l'examen : pas de chute posturale à la lecture de la pression sanguine Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - blood pressure reading NOS Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - blood pressure borderline raised Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some
    On examination - jugular venous pulse Is a False à l'examen : lecture de la pression sanguine Inferred relationship Some

    Reference Sets

    Concept inactivation indicator reference set

    Description inactivation indicator reference set

    GB English

    US English

    MOVED TO association reference set

    Back to Start