FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

422712008: Housing contains unsafe equipment (finding)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2007. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2641436019 Housing contains unsafe equipment (finding) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2645533016 Housing contains unsafe equipment en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2649304012 Residence contains unsafe equipment en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
12767871000172114 équipement dangereux dans le logement fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
3751871000172116 apparatuur in woning onveilig nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
3751881000172118 onveilige apparatuur in huis nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
3751891000172115 huis bevat onveilige apparatuur nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)


2 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Housing contains unsafe equipment (finding) Is a Safety finding true Inferred relationship Some
Housing contains unsafe equipment (finding) Is a Unsatisfactory living conditions true Inferred relationship Some
Housing contains unsafe equipment (finding) Finding method (attribute) History taking true Inferred relationship Some 2
Housing contains unsafe equipment (finding) Interprets Home environment safety status (observable entity) true Inferred relationship Some 1
Housing contains unsafe equipment (finding) Is a Characteristics of home environment - finding true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Housing contains unsafe appliance (finding) Is a True Housing contains unsafe equipment (finding) Inferred relationship Some
Housing contains exposed wiring (finding) Is a True Housing contains unsafe equipment (finding) Inferred relationship Some

Reference Sets

Belgian subset for nursing in patient health records

Back to Start