737011002: revisie van elektrodedraad van biventriculaire implanteerbare cardioverter-defibrillator onder röntgendoorlichting (verrichting)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2018. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3526230015 Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3526231016 Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3526232011 Fluoroscopy guided revision of cardiac biventricular implantable cardioverter defibrillator lead en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
11764961000146110 revisie van draad van biventriculaire cardiale defibrillator onder doorlichting nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
11807821000146116 revisie van elektrodedraad van biventriculaire implanteerbare cardioverter-defibrillator onder röntgendoorlichting (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
11807841000146110 revisie van elektrodedraad van biventriculaire ICD onder röntgendoorlichting nl Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
11807851000146113 fluoroscopisch geleide revisie van lead van tweekamer-ICD nl Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
11807861000146111 revisie van elektrodedraad van biventriculaire implanteerbare cardioverter-defibrillator onder röntgendoorlichting nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
11807871000146117 revisie van geleidingsdraad van implanteerbare tweekamerhartdefibrillator onder röntgendoorlichting nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Operation on heart true Inferred relationship Some
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Cardiac fluoroscopy false Inferred relationship Some
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Cardiac pacemaker procedure false Inferred relationship Some
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Fluoroscopic guidance false Inferred relationship Some
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Biomedical equipment procedure (procedure) false Inferred relationship Some
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 2
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 2
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Heart structure true Inferred relationship Some 2
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Revision status Revision - value true Inferred relationship Some 3
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Method Surgical action true Inferred relationship Some 3
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Direct device Implantable cardioverter leads true Inferred relationship Some 3
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Heart structure true Inferred relationship Some 3
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Revision true Inferred relationship Some
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Fluoroscopy guided cardiac pacemaker procedure true Inferred relationship Some
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Direct device Implantable cardioverter leads true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group