Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2014. Module: SNOMED CT core
Descriptions:
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Esophageal stent procedure using fluoroscopic guidance (procedure) | Is a | interventieradiologie | false | Inferred relationship | Some | ||
Esophageal stent procedure using fluoroscopic guidance (procedure) | Is a | Fluoroscopic guidance | true | Inferred relationship | Some | ||
Esophageal stent procedure using fluoroscopic guidance (procedure) | Is a | verrichting ingedeeld naar hulpmiddel (verrichting) | false | Inferred relationship | Some | ||
Esophageal stent procedure using fluoroscopic guidance (procedure) | Is a | Procedure on esophagus | false | Inferred relationship | Some | ||
Esophageal stent procedure using fluoroscopic guidance (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | false | Inferred relationship | Some | 2 | |
Esophageal stent procedure using fluoroscopic guidance (procedure) | Has intent | Guidance intent (qualifier value) | false | Inferred relationship | Some | 2 | |
Esophageal stent procedure using fluoroscopic guidance (procedure) | Procedure device (attribute) | Stent | true | Inferred relationship | Some | 3 | |
Esophageal stent procedure using fluoroscopic guidance (procedure) | Procedure site - Indirect (attribute) | Oesophageal structure | true | Inferred relationship | Some | 3 | |
Esophageal stent procedure using fluoroscopic guidance (procedure) | Is a | Fluoroscopy of esophagus (procedure) | true | Inferred relationship | Some | ||
Esophageal stent procedure using fluoroscopic guidance (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | true | Inferred relationship | Some | 1 | |
Esophageal stent procedure using fluoroscopic guidance (procedure) | Procedure site - Direct (attribute) | Oesophageal structure | true | Inferred relationship | Some | 1 | |
Esophageal stent procedure using fluoroscopic guidance (procedure) | Direct device | Stent | true | Inferred relationship | Some | 1 | |
Esophageal stent procedure using fluoroscopic guidance (procedure) | Has intent | Guidance intent (qualifier value) | true | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Endoscopic insertion of esophageal stent using fluoroscopic guidance (procedure) | Is a | False | Esophageal stent procedure using fluoroscopic guidance (procedure) | Inferred relationship | Some | |
Endoscopic removal of esophageal stent using fluoroscopic guidance (procedure) | Is a | True | Esophageal stent procedure using fluoroscopic guidance (procedure) | Inferred relationship | Some | |
Fluoroscopy guided insertion of stent into oesophagus | Is a | True | Esophageal stent procedure using fluoroscopic guidance (procedure) | Inferred relationship | Some |
Reference Sets
Description inactivation indicator reference set