FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

703073006: cardiale pacemakerprocedure onder röntgendoorlichting (verrichting)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2014. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3006930011 Fluoroscopy guided cardiac pacemaker procedure en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3006977018 Cardiac pacemaker procedure using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3006981018 Cardiac pacemaker procedure using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
1743281000146116 hartpacemakerprocedure onder doorlichting nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
1743291000146119 cardiale pacemakerprocedure onder röntgendoorlichting (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
2602471000146113 fluoroscopisch geleide cardiale pacemakerprocedure nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
2602771000146119 cardiale pacemakerprocedure onder röntgendoorlichting nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


13 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Fluoroscopy guided cardiac pacemaker procedure Is a Procedure on heart false Inferred relationship Some
Fluoroscopy guided cardiac pacemaker procedure Is a Fluoroscopic guidance true Inferred relationship Some
Fluoroscopy guided cardiac pacemaker procedure Is a interventieradiologie false Inferred relationship Some
Fluoroscopy guided cardiac pacemaker procedure Is a Cardiac pacemaker procedure true Inferred relationship Some
Fluoroscopy guided cardiac pacemaker procedure Procedure device (attribute) Cardiac pacemaker true Inferred relationship Some 2
Fluoroscopy guided cardiac pacemaker procedure Procedure site - Indirect (attribute) Heart structure true Inferred relationship Some 2
Fluoroscopy guided cardiac pacemaker procedure Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 3
Fluoroscopy guided cardiac pacemaker procedure Has intent Guidance intent (qualifier value) false Inferred relationship Some 3
Fluoroscopy guided cardiac pacemaker procedure Is a Biomedical equipment procedure (procedure) true Inferred relationship Some
Fluoroscopy guided cardiac pacemaker procedure Is a Cardiac fluoroscopy true Inferred relationship Some
Fluoroscopy guided cardiac pacemaker procedure Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 1
Fluoroscopy guided cardiac pacemaker procedure Procedure site - Direct (attribute) Heart structure true Inferred relationship Some 1
Fluoroscopy guided cardiac pacemaker procedure Direct device Cardiac pacemaker true Inferred relationship Some 1
Fluoroscopy guided cardiac pacemaker procedure Has intent Guidance intent (qualifier value) true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Insertion of temporary cardiac pacemaker using fluoroscopic guidance (procedure) Is a True Fluoroscopy guided cardiac pacemaker procedure Inferred relationship Some
Revision of internal cardiac defibrillator lead using fluoroscopic guidance (procedure) Is a True Fluoroscopy guided cardiac pacemaker procedure Inferred relationship Some
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Is a True Fluoroscopy guided cardiac pacemaker procedure Inferred relationship Some
Revision of cardiac biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a True Fluoroscopy guided cardiac pacemaker procedure Inferred relationship Some
Repositioning of cardiac pacemaker lead using fluoroscopic guidance (procedure) Is a True Fluoroscopy guided cardiac pacemaker procedure Inferred relationship Some
Fluoroscopy guided removal of cardiac pacemaker Is a True Fluoroscopy guided cardiac pacemaker procedure Inferred relationship Some
Revision of cardiac pacemaker electrode using fluoroscopic guidance Is a True Fluoroscopy guided cardiac pacemaker procedure Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a False Fluoroscopy guided cardiac pacemaker procedure Inferred relationship Some
Fluoroscopy guided implantation of cardiac resynchronization defibrillator system Is a True Fluoroscopy guided cardiac pacemaker procedure Inferred relationship Some

Reference Sets

Description inactivation indicator reference set

Back to Start