FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

50728005: 'evoked response'-audiometrie met elektro-encefalogram (verrichting)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
84544015 Evoked response audiometry with EEG en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
84545019 Brainstem evoked response with EEG en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2688868014 Evoked response audiometry with electroencephalogram (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2696028016 Evoked response audiometry with electroencephalogram en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3275491000146117 'brainstem evoked response'-audiometrie met elektro-encefalogram nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3275501000146110 'evoked response'-audiometrie met elektro-encefalogram (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
4164361000146111 'evoked response'-audiometrie met elektro-encefalogram nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
4164371000146117 BERA met elektro-encefalogram nl Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
4164381000146115 ERA met elektro-encefalogram nl Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Evoked response audiometry with EEG Is a Electroencephalogram true Inferred relationship Some
Evoked response audiometry with EEG Is a Auditory brainstem electric response audiometry (procedure) true Inferred relationship Some
Evoked response audiometry with EEG Method Investigation - action false Inferred relationship Some
Evoked response audiometry with EEG Procedure site Ear structure false Inferred relationship Some 1
Evoked response audiometry with EEG Procedure site Structure of central nervous system (body structure) false Inferred relationship Some 2
Evoked response audiometry with EEG Procedure site Upper respiratory tract structure false Inferred relationship Some 1
Evoked response audiometry with EEG Has intent Diagnostic intent (qualifier value) false Inferred relationship Some 3
Evoked response audiometry with EEG Procedure site Neuromuscular junction (cell structure) false Inferred relationship Some
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 1
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 2
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 2
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 2
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 3
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 1
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 2
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 1
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 2
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 1
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 2
Evoked response audiometry with EEG Method Evaluation - action true Inferred relationship Some 2
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 2
Evoked response audiometry with EEG Method Testing - action false Inferred relationship Some 1
Evoked response audiometry with EEG Procedure site - Direct (attribute) Structure of central nervous system (body structure) true Inferred relationship Some 2
Evoked response audiometry with EEG Procedure site - Direct (attribute) Structure of auditory system (body structure) false Inferred relationship Some 1
Evoked response audiometry with EEG Procedure site - Direct (attribute) Structure of auditory system (body structure) false Inferred relationship Some 1
Evoked response audiometry with EEG Method Testing - action false Inferred relationship Some 1
Evoked response audiometry with EEG Procedure site - Direct (attribute) Structure of central nervous system (body structure) false Inferred relationship Some 2
Evoked response audiometry with EEG Method Evaluation - action false Inferred relationship Some 2
Evoked response audiometry with EEG Procedure site - Direct (attribute) Structure of auditory system (body structure) true Inferred relationship Some 1
Evoked response audiometry with EEG Method Evaluation - action true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start