FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

467503002: drukmeter van cardiopulmonaal bypasscircuit (fysiek object)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2014. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2937954016 Cardiopulmonary bypass system pressure monitor (physical object) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2943437017 Cardiopulmonary bypass system pressure monitor en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
6324071000146112 drukmeter voor hart-longmachine nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
6509751000146112 drukmeter van cardiopulmonaal bypasscircuit nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
6509761000146110 drukmeter van cardiopulmonaal bypasscircuit (fysiek object) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
13292211000146111 Een op het lichtnet (wisselstroom) aangesloten hulpmiddel gebruikt om elektronisch de druk te meten in een hart-longmachine (bv. in het extracorporele slangencircuit); het kan een alarm doen afgaan als de druk de door de gebruiker ingestelde niveaus overschrijdt. Het is doorgaans een onderdeel van de hart-longmachine. nl Definition Active Entire term case sensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Cardiopulmonary bypass system pressure monitor (physical object) Is a Cardiopulmonary bypass circuit false Inferred relationship Some
Cardiopulmonary bypass system pressure monitor (physical object) Is a Cardiovascular monitor (physical object) true Inferred relationship Some
Cardiopulmonary bypass system pressure monitor (physical object) Is a Pressure monitor true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets