Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2014. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2945335014 | Temperature-monitoring indwelling urethral drainage catheter (physical object) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2947535012 | Temperature-monitoring indwelling urethral drainage catheter | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
7041901000146115 | verblijfskatheter voor urethrale drainage met temperatuurbewaking | nl | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Netherlands NRC maintained module (core metadata concept) |
7041921000146111 | verblijfskatheter voor urethrale drainage met temperatuurbewaking (fysiek object) | nl | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Netherlands NRC maintained module (core metadata concept) |
7041911000146118 | Een steriele, flexibele buis met een vulbare ballon aan de distale buistip voor retentie in de urineblaas, na inbrenging via de urethra, waar het functioneert als langdurig inwendig hulpmiddel voor continue urineafvoer en gelijktijdige bewaking van de kerntemperatuur van het lichaam via de integrale temperatuursensor, doorgaans tijdens of na een ingreep of in de aanwezigheid van obstructie of verlamming. Het kan een gebogen tip (coude) hebben om de prostaatbocht makkelijker te kunnen passeren en is doorgaans vervaardigd van silicone. Het wordt ingebracht door getraind personeel en is algemeen bekend als foleykatheter. Dit is een hulpmiddel voor eenmalig gebruik. | nl | Definition | Active | Entire term case sensitive (core metadata concept) | SNOMED CT Netherlands NRC maintained module (core metadata concept) |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Temperature-monitoring indwelling urethral drainage catheter (physical object) | Is a | Urethral drainage catheter | true | Inferred relationship | Some | ||
Temperature-monitoring indwelling urethral drainage catheter (physical object) | Is a | Body aspiration/drainage device | false | Inferred relationship | Some | ||
Temperature-monitoring indwelling urethral drainage catheter (physical object) | Is a | Monitor | false | Inferred relationship | Some | ||
Temperature-monitoring indwelling urethral drainage catheter (physical object) | Is a | Device associated with electrical probes | false | Inferred relationship | Some | ||
Temperature-monitoring indwelling urethral drainage catheter (physical object) | Is a | Balloon dilatation catheter (physical object) | false | Inferred relationship | Some | ||
Temperature-monitoring indwelling urethral drainage catheter (physical object) | Has device intended site (attribute) | Structure of genitourinary system (body structure) | true | Inferred relationship | Some |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets