FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

463732002: microflow-infusiesysteem (fysiek object)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2014. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2943826012 Microflow infusion system (physical object) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2948409010 Microflow infusion system en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
8027261000146110 microflow-infusiesysteem nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
8027281000146119 microflow-infusiesysteem (fysiek object) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
8027271000146116 Een verzameling elektrisch aangedreven hulpmiddelen voor gecontroleerde infusie van therapeutische middelen en vloeistoffen (bv. trombolytica, diagnostische contrastmiddelen) in geselecteerde kleine vaten (onder meer in de neuro-, perifere of coronaire vaatstelsels). Het systeem bestaat doorgaans uit een speciaal voor die toepassing bedoelde microflow-infusiekatheter (ook wel een katheter voor continue spoeling geheten) die gewoonlijk is voorzien van een of meer ultrageluidstranducers met warmtesensor, hulpmiddelen voor vloeistoftoediening en een hulpmiddel dat de aan de katheter geleverde energie voortbrengt en regelt en zo de infusie reguleert. Dit is een herbruikbaar hulpmiddel nadat de verbruikshulpmiddelen zijn aangevuld. nl Definition Active Entire term case sensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Microflow infusion system (physical object) Is a Nervous system catheter false Inferred relationship Some
Microflow infusion system (physical object) Is a Infusion pump (physical object) false Inferred relationship Some
Microflow infusion system (physical object) Is a Catheter false Inferred relationship Some
Microflow infusion system (physical object) Is a Device associated with transducers false Inferred relationship Some
Microflow infusion system (physical object) Is a Device associated with generators false Inferred relationship Some
Microflow infusion system (physical object) Is a Device system (physical object) true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start