FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

444450007: kwantitatief bepalen van massaconcentratie van glucose in peritoneale-dialysevloeistof 4 uur na peritoneale dialyse (verrichting)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2010. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2837007019 Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2841320015 Quantitative measurement of concentration of glucose in peritoneal dialysis fluid at 4 hours postperitoneal dialysis en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2841321016 Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3315711000146118 kwantitatieve bepaling van massaconcentratie van glucose in peritoneaal dialysaat 4 uur na peritoneale dialyse nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3590451000146119 kwantitatief bepalen van massaconcentratie van glucose in peritoneale-dialysevloeistof 4 uur na peritoneale dialyse nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3590461000146116 kwantitatief bepalen van massaconcentratie van glucose in peritoneale-dialysevloeistof 4 uur na peritoneale dialyse (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3651621000146116 kwantitatieve bepaling van massaconcentratie van glucose in PD-vloeistof 4 uur na PD nl Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Is a Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen (procedure) true Inferred relationship Some
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Component Glucose false Inferred relationship Some 2
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Method Measurement - action false Inferred relationship Some 3
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Scale type (attribute) Quantitative false Inferred relationship Some 5
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Has specimen peritonealedialysevloeistof (monster) false Inferred relationship Some 1
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Property (attribute) Mass concentration false Inferred relationship Some 4
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Has specimen Peritoneal dialysate specimen true Inferred relationship Some 1
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Scale type (attribute) Quantitative true Inferred relationship Some 1
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Method Measurement - action true Inferred relationship Some 1
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Property (attribute) Mass concentration true Inferred relationship Some 1
Quantitative measurement of mass concentration of glucose in peritoneal dialysis fluid specimen at 4 hours postperitoneal dialysis (procedure) Component Glucose true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

GB English

US English

Back to Start