FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

438605009: bepaling van T-topveranderingen op microvoltniveau ter beoordeling van ventriculaire aritmie (verrichting)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2009. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2786596019 Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2792334018 Measurement of microvolt T wave alternans for ventricular arrhythmia assessment en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2108861000146116 bepaling van T-topveranderingen op microvoltniveau ter beoordeling van ventriculaire aritmie nl Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
2108871000146110 bepaling van T-topveranderingen op microvoltniveau ter beoordeling van ventriculaire aritmie (verrichting) nl Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Is a Electrocardiographic procedure false Inferred relationship Some
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Is a Procedure for arrhythmia true Inferred relationship Some
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Has focus Conduction disorder of the heart false Inferred relationship Some
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Using device (attribute) Electrocardiographic monitor and recorder false Inferred relationship Some 1
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Method Monitoring - action false Inferred relationship Some 1
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Procedure site - Direct (attribute) Heart structure false Inferred relationship Some 1
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Procedure site - Direct (attribute) Heart structure true Inferred relationship Some 1
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Method Monitoring - action true Inferred relationship Some 1
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Using device (attribute) Electrocardiographic monitor and recorder true Inferred relationship Some 1
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Is a Electrocardiographic monitoring true Inferred relationship Some
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment (procedure) Has focus Cardiac arrhythmia (disorder) true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start