FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

432375008: insertie van intra-aortale ballonpomp onder röntgendoorlichting (verrichting)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2008. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4009169012 Fluoroscopic guidance for insertion of intra-aortic balloon pump with contrast en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4009170013 Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
4009171012 Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1864611000146117 inbrengen van intra-aortale ballonpomp onder doorlichting nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
1864631000146112 inbrengen van IABP onder doorlichting nl Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
1864641000146116 fluoroscopisch geleid inbrengen van intra-aortale ballonpomp nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
2402981000146116 insertie van intra-aortale ballonpomp onder röntgendoorlichting nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
2402991000146119 insertie van intra-aortale ballonpomp onder röntgendoorlichting (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Is a Fluoroscopic angiography of aorta with contrast (procedure) true Inferred relationship Some
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Is a insertie in aorta false Inferred relationship Some
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Is a Insertion using fluoroscopic guidance (procedure) true Inferred relationship Some
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Is a Insertion of infusion pump (procedure) false Inferred relationship Some
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Method Insertion - action (qualifier value) false Inferred relationship Some 1
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Direct device Intra-aortic balloon pump false Inferred relationship Some 1
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Procedure site - Indirect (attribute) Aortic structure false Inferred relationship Some 1
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 2
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Has intent Guidance intent (qualifier value) false Inferred relationship Some 2
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Aortic structure false Inferred relationship Some 2
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Is a Procedure on aorta using imaging guidance (procedure) true Inferred relationship Some
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Procedure site - Indirect (attribute) Aortic structure true Inferred relationship Some 1
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Direct device Intra-aortic balloon pump true Inferred relationship Some 1
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Method Insertion - action (qualifier value) true Inferred relationship Some 1
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Aortic structure true Inferred relationship Some 2
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 2
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 2
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Is a Insertion of intra-aortic balloon counterpulsation (procedure) true Inferred relationship Some
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Using substance (attribute) Contrast media (substance) true Inferred relationship Some 2
Insertion of intra-aortic balloon pump using fluoroscopic guidance with contrast (procedure) Direct device Intra-aortic balloon pump true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start