FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

427064004: continue saturatiemeting per pulsoxymeter (verrichting)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2007. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2661939012 Continuous pulse oximetry (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2675999015 Continuous pulse oximetry en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3552581000146119 continue saturatiemeting per pulsoxymeter nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3572171000146110 continue pulsoxymetrie nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3745601000146117 continue saturatiemeting per pulsoxymeter (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Continuous pulse oximetry (procedure) Is a Pulse oximetry (procedure) true Inferred relationship Some
Continuous pulse oximetry (procedure) Using device (attribute) Oxygen analyzer false Inferred relationship Some 2
Continuous pulse oximetry (procedure) Has specimen Arterial blood specimen false Inferred relationship Some
Continuous pulse oximetry (procedure) Component Hydrogen ion concentration false Inferred relationship Some
Continuous pulse oximetry (procedure) Has intent Diagnostic intent (qualifier value) false Inferred relationship Some
Continuous pulse oximetry (procedure) Property (attribute) Substance concentration false Inferred relationship Some
Continuous pulse oximetry (procedure) Method Evaluation - action false Inferred relationship Some 2
Continuous pulse oximetry (procedure) Component Oxygen false Inferred relationship Some
Continuous pulse oximetry (procedure) Method Measurement - action true Inferred relationship Some 2
Continuous pulse oximetry (procedure) Method Evaluation - action false Inferred relationship Some 3
Continuous pulse oximetry (procedure) Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 2
Continuous pulse oximetry (procedure) Procedure site Respiratory tract structure false Inferred relationship Some 3
Continuous pulse oximetry (procedure) Method Measurement - action false Inferred relationship Some 1
Continuous pulse oximetry (procedure) Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Continuous pulse oximetry (procedure) Method Measurement - action false Inferred relationship Some
Continuous pulse oximetry (procedure) Component Substance false Inferred relationship Some
Continuous pulse oximetry (procedure) Using device (attribute) Pulse oximeter (physical object) false Inferred relationship Some 1
Continuous pulse oximetry (procedure) Method Measurement - action false Inferred relationship Some 1
Continuous pulse oximetry (procedure) Using device (attribute) Pulse oximeter (physical object) true Inferred relationship Some 2
Continuous pulse oximetry (procedure) Component Oxyhemoglobin true Inferred relationship Some 2
Continuous pulse oximetry (procedure) Property (attribute) Quantity fraction true Inferred relationship Some 2
Continuous pulse oximetry (procedure) Scale type (attribute) Quantitative true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start