FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

38001000: monitoren van pacemaker (regime/therapie)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
63378010 Monitoring of pacemaker en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1458775019 Monitoring of pacemaker (regime/therapy) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
484191000146111 pacemakercontrole nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
586291000146116 controle van pacemaker nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
1322641000146116 monitoren van pacemaker nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
1322651000146118 monitoren van pacemaker (regime/therapie) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


2 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Monitoring of pacemaker Is a Cardiotachometry true Inferred relationship Some
Monitoring of pacemaker Procedure site Heart structure false Inferred relationship Some
Monitoring of pacemaker Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some
Monitoring of pacemaker Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Monitoring of pacemaker Method Monitoring - action false Inferred relationship Some 1
Monitoring of pacemaker Method Monitoring - action true Inferred relationship Some 1
Monitoring of pacemaker Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Monitoring of pacemaker Procedure site Heart structure true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Monitoring, evaluation and adjustment of settings of cardiac pacemaker Is a True Monitoring of pacemaker Inferred relationship Some
Remote monitoring of cardiac pacemaker Is a True Monitoring of pacemaker Inferred relationship Some

Reference Sets

GB English

US English

Back to Start