FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

360152008: monitoren (kwalificatiewaarde)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
475807013 Monitoring - action en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
739693013 Monitoring - action (qualifier value) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
1045241000146112 bewaken nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
1322461000146118 monitoren (kwalificatiewaarde) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
1322471000146112 monitoren nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Monitoring - action Is a Observation - action false Inferred relationship Some
Monitoring - action Is a Evaluation - action true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Monitoring of pressure in ventricle of brain (regime/therapy) Method False Monitoring - action Inferred relationship Some 1
Monitoring procedure Method False Monitoring - action Inferred relationship Some
Core temperature monitoring Method False Monitoring - action Inferred relationship Some
Rectal temperature taking Method False Monitoring - action Inferred relationship Some
Intracranial/cerebral perfusion pressure monitoring Method False Monitoring - action Inferred relationship Some
Systemic arterial pressure monitoring Method False Monitoring - action Inferred relationship Some 1
Metabolic monitoring procedure Method False Monitoring - action Inferred relationship Some
Measurement of systemic arterial pressure Method False Monitoring - action Inferred relationship Some 2
Arterial pressure monitoring, invasive method Method False Monitoring - action Inferred relationship Some 1
Rhythm strip monitoring Method True Monitoring - action Inferred relationship Some 1
Oral temperature taking Method False Monitoring - action Inferred relationship Some
Compartment pressure studies (procedure) Method False Monitoring - action Inferred relationship Some
Postoperative monitoring (regime/therapy) Method True Monitoring - action Inferred relationship Some 1
Monitoring of patient temperature Method False Monitoring - action Inferred relationship Some
Arterial pressure monitoring, non-invasive method Method False Monitoring - action Inferred relationship Some 1
Evaluation of postoperative neurological status Method True Monitoring - action Inferred relationship Some 1
Temperature gradient studies Method True Monitoring - action Inferred relationship Some 1
Phonocardiogram with ECG lead Method False Monitoring - action Inferred relationship Some 1
standaardelektrocardiografie (verrichting) Method False Monitoring - action Inferred relationship Some 1
Ambulatory ECG Method False Monitoring - action Inferred relationship Some 1
Percutaneous transluminal mapping of conducting system of heart Method False Monitoring - action Inferred relationship Some 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Method False Monitoring - action Inferred relationship Some 2
Monitoring of patient Method True Monitoring - action Inferred relationship Some 1
Neurological monitoring regime (regime/therapy) Method True Monitoring - action Inferred relationship Some 1
Intracranial pressure monitoring regime Method True Monitoring - action Inferred relationship Some 1
Spinal cord function monitoring Method True Monitoring - action Inferred relationship Some 1
Cardiac output monitoring Method False Monitoring - action Inferred relationship Some 1
Continuous fetal heart monitoring during labor (regime/therapy) Method False Monitoring - action Inferred relationship Some 1
Intermittent fetal heart monitoring during labor (regime/therapy) Method False Monitoring - action Inferred relationship Some 1
Fetal heart monitoring using hand held Doppler Method False Monitoring - action Inferred relationship Some 1
Fetal heart monitoring using fetal scalp electrode (regime/therapy) Method False Monitoring - action Inferred relationship Some 1
Fetal heart monitoring using ultrasound transducer (regime/therapy) Method False Monitoring - action Inferred relationship Some 1
Uterine contraction monitoring using external transducer (regime/therapy) Method False Monitoring - action Inferred relationship Some 1
Uterine contraction monitoring using intrauterine pressure catheter (regime/therapy) Method False Monitoring - action Inferred relationship Some 1
Fetal heart monitoring with Pinard stethoscope (regime/therapy) Method False Monitoring - action Inferred relationship Some 1
Procedure for monitoring intracranial pressure Method False Monitoring - action Inferred relationship Some 1
Insertion of intracranial pressure measuring device Method False Monitoring - action Inferred relationship Some 2
Insertion of intracranial pressure transducer (procedure) Method False Monitoring - action Inferred relationship Some 2
Insertion of intracranial pressure catheter (procedure) Method False Monitoring - action Inferred relationship Some 2
Attention to intracranial pressure measuring device Method False Monitoring - action Inferred relationship Some 1
Attention to intracranial pressure transducer (procedure) Method False Monitoring - action Inferred relationship Some 1
Revision of intracranial pressure transducer Method False Monitoring - action Inferred relationship Some 1
Attention to intracranial pressure catheter Method False Monitoring - action Inferred relationship Some 2
Revision of intracranial pressure catheter Method False Monitoring - action Inferred relationship Some 2
Removal of intracranial pressure transducer (procedure) Method False Monitoring - action Inferred relationship Some 2
Removal of intracranial pressure catheter Method False Monitoring - action Inferred relationship Some 1
Intracardiac electrophysiologic procedure with ECG Method False Monitoring - action Inferred relationship Some 1
24 Hour ECG Method False Monitoring - action Inferred relationship Some 1
Intraoperative neurophysiological monitoring Method False Monitoring - action Inferred relationship Some 3
Intraoperative sensory nerve stimulation Method False Monitoring - action Inferred relationship Some 3
Intraoperative motor nerve stimulation Method False Monitoring - action Inferred relationship Some 3
Intraoperative facial nerve stimulation Method False Monitoring - action Inferred relationship Some 3
Antepartum cardiotochogram Method True Monitoring - action Inferred relationship Some 1
Recovery room monitoring, anesthesia Method True Monitoring - action Inferred relationship Some 1
Obstetric monitoring Method True Monitoring - action Inferred relationship Some 1
Intraoperative EEG - cerebral function analysing monitor Method False Monitoring - action Inferred relationship Some 3
Intraoperative EEG using compressed spectral array Method False Monitoring - action Inferred relationship Some 3
Fetal heart monitoring Method False Monitoring - action Inferred relationship Some 1
Fetal heart monitoring in labor Method False Monitoring - action Inferred relationship Some 1
Physiological monitoring regime (regime/therapy) Method True Monitoring - action Inferred relationship Some 1
Evoked potentials monitoring Method True Monitoring - action Inferred relationship Some 1
Visual evoked potentials monitoring Method True Monitoring - action Inferred relationship Some 1
Auditory evoked potentials monitoring Method True Monitoring - action Inferred relationship Some 1
Neuromuscular blockade monitoring Method True Monitoring - action Inferred relationship Some 1
Respiratory rate monitoring Method True Monitoring - action Inferred relationship Some 2
Respiratory volume monitoring Method True Monitoring - action Inferred relationship Some 2
Airway pressure monitoring Method True Monitoring - action Inferred relationship Some 2
ECG ST segment monitoring Method False Monitoring - action Inferred relationship Some 1
ECG automated dysrhythmia monitoring Method False Monitoring - action Inferred relationship Some 1
Vascular pressure monitoring Method False Monitoring - action Inferred relationship Some 1
Continuous auscultation monitoring Method False Monitoring - action Inferred relationship Some 1
Peripheral temperature monitoring Method True Monitoring - action Inferred relationship Some 1
Respiratory gas monitoring Method True Monitoring - action Inferred relationship Some 2
Respired carbon dioxide monitoring Method True Monitoring - action Inferred relationship Some 2
Anesthetic agent monitoring Method True Monitoring - action Inferred relationship Some 2
Continuous invasive blood gas monitoring Method False Monitoring - action Inferred relationship Some 1
Oxygenation monitoring Method True Monitoring - action Inferred relationship Some 1
Invasive oxygen saturation monitoring Method True Monitoring - action Inferred relationship Some 2
Pulse oximetry monitoring Method True Monitoring - action Inferred relationship Some 2
Transcutaneous oxygen monitoring Method True Monitoring - action Inferred relationship Some 1
Equipment monitoring Method False Monitoring - action Inferred relationship Some
Fresh gas oxygen concentration monitoring Method False Monitoring - action Inferred relationship Some
Oxygen supply failure monitoring Method False Monitoring - action Inferred relationship Some
Breathing system disconnection monitoring Method False Monitoring - action Inferred relationship Some
Preventive monitoring Method True Monitoring - action Inferred relationship Some 1
Multisystem physiological monitoring regime Method True Monitoring - action Inferred relationship Some 1
Monitoring of temperature, pulse rate and respiratory rate Method True Monitoring - action Inferred relationship Some 1
Monitoring of blood pressure, temperature, pulse rate and respiratory rate Method True Monitoring - action Inferred relationship Some 2
Intrapartum cardiotochogram monitoring Method False Monitoring - action Inferred relationship Some 1
Voice monitoring Method True Monitoring - action Inferred relationship Some 1
Monitoring of coronary blood flow Method False Monitoring - action Inferred relationship Some 1
Intracranial pressure monitor removal Method False Monitoring - action Inferred relationship Some 2
Hemodynamic measurement via dual catheter method (regime/therapy) Method False Monitoring - action Inferred relationship Some 2
Hemodynamic measurement via pulmonary capillary wedge method Method False Monitoring - action Inferred relationship Some 2
Hemodynamic measurement via pullback method (regime/therapy) Method False Monitoring - action Inferred relationship Some 2
Computed hemodynamic measurement method Method True Monitoring - action Inferred relationship Some 2
Composite hemodynamic measurement method Method True Monitoring - action Inferred relationship Some 2
Static catheter hemodynamic measurement method (regime/therapy) Method True Monitoring - action Inferred relationship Some 2
Hemodynamic measurement via wedge method (regime/therapy) Method False Monitoring - action Inferred relationship Some 2
Averaged haemodynamic measurement method Method True Monitoring - action Inferred relationship Some 2
Fluid filled catheter hemodynamic measurement method (regime/therapy) Method False Monitoring - action Inferred relationship Some 2

Page 1 of 10 Next End


This concept is not in any reference sets

Back to Start