Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Nov 2022. Module: SNOMED CT core
Descriptions:
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Is a | Plain X-ray of chest (procedure) | true | Inferred relationship | Some | ||
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Procedure site - Direct (attribute) | Breast structure | true | Inferred relationship | Some | 2 | |
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Is a | Biopsy of breast using mammography guidance (procedure) | false | Inferred relationship | Some | ||
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Is a | Plain X-ray guidance | false | Inferred relationship | Some | ||
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Is a | Vacuum assisted biopsy (procedure) | false | Inferred relationship | Some | ||
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Method | Biopsy - action | true | Inferred relationship | Some | 1 | |
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Procedure site - Direct (attribute) | Breast structure | true | Inferred relationship | Some | 1 | |
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Using device (attribute) | Vacuum aspirator | true | Inferred relationship | Some | 1 | |
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Method | Plain X-ray imaging - action (qualifier value) | true | Inferred relationship | Some | 2 | |
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Using device (attribute) | Stereotactic device | true | Inferred relationship | Some | 2 | |
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Has intent | Guidance intent (qualifier value) | true | Inferred relationship | Some | 2 | |
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Is a | Vacuum assisted biopsy of breast using imaging guidance (procedure) | true | Inferred relationship | Some | ||
Upright vacuum assisted biopsy of breast using stereotactic plain X-ray guidance (procedure) | Is a | Plain X-ray guided biopsy | true | Inferred relationship | Some |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets