FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

175130004: percutaan transluminaal mappen van geleidingssysteem van hart (verrichting)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2008. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
271214011 Percutaneous transluminal mapping of conducting system of heart en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
557643013 Percutaneous transluminal mapping of conducting system of heart (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3371231000146110 percutaan transluminaal mappen van geleidingssysteem van hart nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3371241000146119 percutaan transluminaal mappen van geleidingssysteem van hart (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3371251000146116 percutaan transluminaal in kaart brengen van geleidingssysteem van hart nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


1 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Percutaneous transluminal mapping of conducting system of heart Is a diagnostische verrichting op hart false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Is a Cardiac mapping true Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Is a Medical procedure on heart false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Is a Procedure for arrhythmia false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Method Measurement - action true Inferred relationship Some 1
Percutaneous transluminal mapping of conducting system of heart Has intent Diagnostic intent (qualifier value) false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Approach Transluminal approach false Inferred relationship Some 1
Percutaneous transluminal mapping of conducting system of heart Access Percutaneous approach true Inferred relationship Some 1
Percutaneous transluminal mapping of conducting system of heart Procedure site Cardiac conducting system structure false Inferred relationship Some 1
Percutaneous transluminal mapping of conducting system of heart Method Investigation - action false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Using Electrocardiographic monitor and recorder false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Is a Anatomic measurement false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Direct device Electrocardiographic monitor and recorder false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Using Electrocardiographic monitor and recorder false Inferred relationship Some 2
Percutaneous transluminal mapping of conducting system of heart Is a Procedure by transluminal approach false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 2
Percutaneous transluminal mapping of conducting system of heart Has focus Conduction disorder of the heart false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Method Monitoring - action false Inferred relationship Some 2
Percutaneous transluminal mapping of conducting system of heart Is a Anatomic measurement false Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Using device (attribute) Electrocardiographic monitor and recorder false Inferred relationship Some 2
Percutaneous transluminal mapping of conducting system of heart Procedure site - Direct (attribute) Structure of cardiovascular system (body structure) false Inferred relationship Some 2
Percutaneous transluminal mapping of conducting system of heart Procedure site - Direct (attribute) Cardiac conducting system structure true Inferred relationship Some 1
Percutaneous transluminal mapping of conducting system of heart Method Measurement - action false Inferred relationship Some 1
Percutaneous transluminal mapping of conducting system of heart Access Percutaneous approach false Inferred relationship Some 1
Percutaneous transluminal mapping of conducting system of heart Procedure site - Direct (attribute) Cardiac conducting system structure false Inferred relationship Some 1
Percutaneous transluminal mapping of conducting system of heart Is a Measurement true Inferred relationship Some
Percutaneous transluminal mapping of conducting system of heart Has focus Cardiac arrhythmia (disorder) false Inferred relationship Some 2
Percutaneous transluminal mapping of conducting system of heart Has intent Diagnostic intent (qualifier value) false Inferred relationship Some 3
Percutaneous transluminal mapping of conducting system of heart Is a Procedure on heart true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Percutaneous transluminal three dimensional electroanatomic mapping of conducting system of heart (procedure) Is a True Percutaneous transluminal mapping of conducting system of heart Inferred relationship Some

This concept is not in any reference sets

Back to Start