Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Nov 2022. Module: SNOMED CT core
Descriptions:
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Implantation of spinal cord stimulator generator and electrode (procedure) | Is a | Procedure on trunk | true | Inferred relationship | Some | ||
Implantation of spinal cord stimulator generator and electrode (procedure) | Is a | Procedure on subcutaneous tissue | false | Inferred relationship | Some | ||
Implantation of spinal cord stimulator generator and electrode (procedure) | Is a | Implantation of electronic stimulator of spine | true | Inferred relationship | Some | ||
Implantation of spinal cord stimulator generator and electrode (procedure) | Is a | Implantation of neurostimulator device (procedure) | false | Inferred relationship | Some | ||
Implantation of spinal cord stimulator generator and electrode (procedure) | Method | Implantation - action | true | Inferred relationship | Some | 1 | |
Implantation of spinal cord stimulator generator and electrode (procedure) | Procedure site - Indirect (attribute) | Spinal cord structure | true | Inferred relationship | Some | 1 | |
Implantation of spinal cord stimulator generator and electrode (procedure) | Direct device | Neurostimulator electrode | true | Inferred relationship | Some | 1 | |
Implantation of spinal cord stimulator generator and electrode (procedure) | Method | Implantation - action | true | Inferred relationship | Some | 2 | |
Implantation of spinal cord stimulator generator and electrode (procedure) | Procedure site - Indirect (attribute) | Subcutaneous tissue structure of trunk (body structure) | true | Inferred relationship | Some | 2 | |
Implantation of spinal cord stimulator generator and electrode (procedure) | Direct device | Implantable analgesic spinal cord electrical stimulation system pulse generator | true | Inferred relationship | Some | 2 | |
Implantation of spinal cord stimulator generator and electrode (procedure) | Is a | introduceren van substantie in subcutaan weefsel | false | Inferred relationship | Some | ||
Implantation of spinal cord stimulator generator and electrode (procedure) | Is a | Introduction into subcutaneous tissue | true | Inferred relationship | Some | ||
Implantation of spinal cord stimulator generator and electrode (procedure) | Is a | Implantation of neurostimulator device of spinal cord | true | Inferred relationship | Some |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets