FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

100301000146107: inspanningstest met draagbare spiro-ergometer (verrichting)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Sep 2019. Module: SNOMED CT Netherlands NRC maintained module (core metadata concept)

Descriptions:

Id Description Lang Type Status Case? Module
4476011000146112 Excercise test with portable spiroergometer (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
4476021000146119 Excercise test with portable spiroergometer en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
6917571000146114 inspanningstest met draagbare spiro-ergometer nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
6917581000146111 inspanningstest met draagbare spiro-ergometer (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Excercise test with portable spiroergometer (procedure) Has intent Diagnostic intent (qualifier value) false Inferred relationship Some 2
Excercise test with portable spiroergometer (procedure) Direct device Meters true Inferred relationship Some 1
Excercise test with portable spiroergometer (procedure) Method Measurement - action true Inferred relationship Some 3
Excercise test with portable spiroergometer (procedure) Is a Exercise tolerance test true Inferred relationship Some
Excercise test with portable spiroergometer (procedure) Method Evaluation - action true Inferred relationship Some 1
Excercise test with portable spiroergometer (procedure) Procedure site Structure of cardiovascular system (body structure) true Inferred relationship Some 1
Excercise test with portable spiroergometer (procedure) Is a Biomedical equipment procedure (procedure) true Inferred relationship Some
Excercise test with portable spiroergometer (procedure) Is a Spirometry true Inferred relationship Some
Excercise test with portable spiroergometer (procedure) Is a diagnostische verrichting ingedeeld naar anatomische of verworven lichaamsstructuur false Inferred relationship Some
Excercise test with portable spiroergometer (procedure) Is a diagnostische verrichting false Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start